GX10-95/2 Marathon Industrial ilsco power Distribution Terminal Electrical Blocks
Feature: Modular design, cascading with each other, compact structure Use flame retardant engineering materials, adequate strength and hardness to prevent short circuit and flame retardant design.
Advantage
* Save 50%-70% cost comparing to busbar and branch cables
* Provides flexible connection solution with combinations
* Patented design provides reliable and wide area contact
* Low resistance contact points
* Molded with anti-aging, non-flammable, heat & impact resistance material, passed 160A/mm2 short-circuits stress test and UL 94 V-0 flammability test
Details parameters
| Product Description | ||||
| Product Image | ||||
| Product Number | GX10-95 | GX10-95/2 | GX10-150 | GX10-240 |
| Product Type | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block |
| Mechanical Structure | Thread type connection | Thread type connection | Thread type connection | Thread type connection |
| Layers | 1 | 1 | 1 | 1 |
| Electric Potential | 2 | 4 | 2 | 2 |
| Connection Volume | 2 | 4 | 2 | 2 |
| Rated Cross Section | 50-95mm2 | 50-95mm2 | 50-150mm2 | 95-240mm2 |
| Rated Current | 245A | 245A | 320A | 425 |
| Rated Voltage | 1000V | 1000V | 1000V | 1000V |
| Open Side Panel | Yes | Yes | Yes | Yes |
| Grounding Feet | no | no | no | no |
| Other | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 | The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 |
| Application Field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
| Color | (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable | (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable | (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable | (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable |
| Wiring Data | ||||
| Line Contact | ||||
| Stripping Length | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm |
| Rigid Conductor Cross Section | 50mm² — 95mm² | 50mm² — 95mm² | 50mm² — 150mm² | 95mm² — 240mm² |
| Flexible Conductor Cross Section | 50mm² — 95mm² | 50mm² — 95mm² | 50mm² — 150mm² | 95mm² — 240mm² |
| Rigid Conductor Cross Section AWG | 1/0~6 | 1/0~6 | 1/0~6 | 1/0~6 |
| Flexible Conductor Cross Section AWG | 1/0~6 | 1/0~6 | 1/0~6 | 1/0~6 |
| Size | ||||
| Thickness | 42mm | 42mm | 28.6mm | 37mm |
| Width | 89mm | 89mm | 98mm | 130mm |
| High | 51.5mm | 51.5mm | 60.5mm | 66mm |
| NS35/7.5 High | 59mm | 59mm | 68mm | 73.5mm |
| NS35/15 High | - | - | - | |
| NS15/5.5 High | ||||
| Material Properties | ||||
| Flame Retardant Grade, In Line With UL94 | V0 | V0 | V0 | V0 |
| Insulation Materials | PA | PA | PA | PA |
| Insulation Material Group | I | I | I | I |
| IEC Electrical Parameters | ||||
| 测试标准 Standard Test | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 |
| Rated Voltage(III/3) | 1000V | 1000V | 1000V | 1000V |
| Rated Current(III/3) | 245A | 245A | 320A | 425A |
| Rated Surge Voltage | 8kv | 8kv | 8kv | 8kv |
| Overvoltage Class | III | III | III | III |
| Pollution Level | 3 | 3 | 3 | 3 |
| Electrical Performance Test | ||||
| Surge Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test |
| Power Frequency Withstand Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test |
| Temperature Rise Test Results | Passed the test | Passed the test | Passed the test | Passed the test |
| Environmental Conditions | ||||
| Ambient Temperature (Operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
| Ambient Temperature (Storage/Transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
| Ambient Temperature (Assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
| Ambient Temperature (Execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
| Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
| Environmental Friendly | ||||
| RoHS | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values | No hazardous substances above threshold values |
| Standards And Specifications | ||||
| Connections Are Standard | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 | EN61238-1,EN60947-7-2 |